Recommended insulation levels for retrofitting existing wood framed buildings.
Attic insulation florida code.
Insulation requirements in florida.
For block walls interior insulation must meet or exceed r 7 8 and exterior insulation must be r 6.
Section r316 local codes based on irc 2012.
Broward collier hendry lee miami dade monroe and palm beach and require a minimum r 30 attic insulation.
The florida building code identifies two distinct climate zones.
Achieving greater r values in attics the higher the r value the better the thermal performance of the insulation.
Find your zone on the map and then use the chart to determine the level of insulation you need to properly insulate your attic walls floors and crawlspaces.
When designing and building an unvented attic using spray foam insulation you need to take into account code related to.
Add insulation to attic.
Framed wall insulation must meet or exceed r 13.
50 pa in accordance with section r402 4 1 2 of the florida building code energy conservation residential provisions the dwelling unit shall be ventilated by mechanical means in accordance with section 403 of the florida building code mechanical.
Most insulation you buy will have a sq ft number for easy reference.
Section 402 4 2 of the code requires building air tightness and insulation installation to be demonstrated as compliant with the code.
Section r806 5 spray foam code local codes based on irc 2009.
Here s what you need to know about insulation requirements in florida.
Where the air infiltration rate in a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure 0 2 inch w c.
Residential requirements for insulation are divided by the location in the home.
Existing 3 4 inches of insulation.
It provides the option of testing with a blower door to demonstrate that air leakage is less than 7 ach or that tightness be considered acceptable when items.
All florida insulation proper insulation levels for attic insulation in orlando maitland lake mary longwood gotha call 407 410 3626 for a free quote.
Typically current best home building practices indicate an r 30 to r 38 for attic insulation.
Climate zone 1 consists of the following south florida counties.
Section r806 4 local codes based on irc 2012.
In climate zones 5 6 7 and 8 of table r301 1 of the florida building code energy conservation any air impermeable insulation shall be a class ii vapor retarder or shall have a class iii vapor retarder coating or covering in direct contact with the underside of the insulation.