Calculations indicate that on a july day in texas a ventilation rate of one air change per minute for a typical attic using 95 degree f air will lower the peak attic temperature to about 101 degrees f.
Attic ventilation requirements texas.
Mechanical ventilation shall be provided by a method of supply air and return or exhaust air except that mechanical ventilation air requirements for group r 2 r 3 and r 4 occupancies three stories and less in height above grade plane shall be provided by an exhaust system supply system or combination thereof.
If you live in the texas panhandle consider increasing your insulation level to at least r 38.
The minimum service entrance shall be 100 amperes with a 3 wire 120 240 volt single phase service with a grounded neutral.
Once they are in place you can then place the batts or blankets or blow insulation right out to the very edge of the attic floor.
You can also contact your local municipality to check on building code in your area.
A 30 inch minimum clear headroom in the attic space shall be provided at or above the access opening.
Tips for assessing your needs.
For a 200 amp service the nominal size shall be no.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The nominal size of wire used with a 100 amp service shall be no.
Most building codes require a ratio of 1 150 ventilation space to attic floor space.
Of vent for every 300 sq.
Regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
Rafter vents should be placed in your attic ceiling in between the rafters at the point where your attic ceiling meets your attic floor.
An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Building codes vary.
Providing half air change per minute will lower the temperature to about 106 degrees f.
For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing.
Uninsulated attic spaces are responsible for significant heat loss since heat rises in a building.